What size heat pump do I need? Halifax size calculator
What size heat pump do you need? For most single detached Halifax houses the heating load is between about 20,000 and 100,000 BTU/h, depending mostly on how big the house is and when it was built. BTU/h is how much heat the house loses each hour on the coldest design night, and the heat pump has to replace that heat. The calculator below turns three answers about your house into a size range and the equipment sizes that match it.
Around Halifax
A heat pump in Halifax is sized for the coldest stretch of the winter, not for an average day. The design temperature here is -16 degrees Celsius, and in January it is colder than that for about 19 hours on average. That is why a house with oil or baseboards often keeps them: a heat pump that covers 100 percent of the load on those few hours would be much bigger than it needs to be the rest of the winter.
Your estimate
That points to about:
Why this number
An estimate from national energy evaluations of Halifax-area single detached houses (EnerGuide open data, 2025 file), the National Building Code of Canada 2020 (design temperature and indoor temperature) and the federal ASHP sizing guide (equipment, backup heat). All checked on 2026-10-30; full list under Sources below.
That size is outside what our data covers. Ask an installer for a room-by-room heat-loss calculation (CSA F280) for your house.
An estimate, not a design. An installer measures your home and does a full room-by-room heat-loss calculation (CSA F280) before recommending equipment. Single detached houses only.
What size heat pump does a typical Halifax house need?
Here’s the same math the calculator uses, for houses with a basement, at four sizes. The size in each row is the above-ground living area, not counting the basement. Each cell shows the range for most homes like yours in thousands of BTU/h, then the ducted size that fits the middle of that range. It works without JavaScript, so you’ll always see it.
| Above ground | 2010 or later | 1980 to 2009 | Before 1980 |
|---|---|---|---|
| 1,000 sq ft | 18 to 24k2-ton ducted | 25 to 35k2.5-ton ducted | 33 to 46k3.5-ton ducted |
| 1,500 sq ft | 23 to 32k2.5-ton ducted | 31 to 43k3-ton ducted | 45 to 63k4.5-ton ducted |
| 2,000 sq ft | 28 to 40k3-ton ducted | 37 to 51k4-ton ducted | 58 to 80kducted: over 5-ton |
| 2,500 sq ft | 34 to 47k3.5-ton ducted | 43 to 60k4.5-ton ducted | 70 to 97kducted: over 5-ton |
BTU/h in thousands for most homes like yours, at -16 °C outside. The ducted size fits the typical house in the range.
Newer houses lose less heat because they have more insulation and fewer air leaks, which is why the same floor area needs a smaller unit as you move right. A house built before 1980 may still have most of its original walls, windows and attic insulation, and upgrades move it toward the newer columns.
How is the heat pump size calculated?
Heat flows out of a house at a rate that depends on the temperature difference between inside and outside. So the size comes from three things:
- The design temperature difference. The code uses 22 degrees Celsius inside and -16 degrees outside for Halifax. That is a difference of 38 degrees Celsius, or 68.4 degrees Fahrenheit.
- How much heat the house loses per degree. This is measured in BTU/h for every degree Fahrenheit of difference. It grows with the size of the house and is lower for newer houses and for houses without a basement.
- The spread between similar houses. Real houses vary. The range shows where the middle half of similar houses fall, and the large number is the typical house.
The heat loss per degree comes from energy evaluations of real Halifax-area houses. For each age group, a straight line links the above-ground living area to the heat loss, with and without a basement. Multiplying by the design difference gives the load. The headline figure is the typical house, a little below that line, and the range runs from 19 percent below to 13 percent above the line.
The calculator covers single detached houses from 600 to 3,500 square feet above ground. Row houses, duplexes and mobile homes aren’t in the data, so a number for those would be a guess.
Which heat pump sizes does the estimate point to?
Heat pumps are sold in set sizes. Ductless mini-split heads come as 9,000, 12,000 and 18,000 BTU/h, and a single outdoor unit can feed up to four heads. Ducted systems come in half-ton steps, and one ton is 12,000 BTU/h. The calculator picks the smallest size at or above the typical house, which is what the headline figure comes from.
A cold-climate heat pump delivers less than its label when it’s very cold outside. The calculator assumes 90 percent of the label at -16 degrees Celsius. A standard model delivers much less, so ask any installer for the capacity at -16 degrees Celsius from the maker’s own table.
When the delivered capacity covers 100 percent of the load, no backup is needed at -16 degrees Celsius on paper. When it covers less, the shortfall is what your backup heat has to supply on the coldest hours. Baseboards, an oil furnace or a wood stove all work.
Why not buy a bigger heat pump to be safe?
A heat pump that’s much bigger than the house needs reaches the set temperature quickly, switches itself off and starts again soon after. That cycling is hard on the equipment and wastes energy. A unit matched to the load runs longer and steadier, which is where it works best.
Sources
Checked on 2026-10-30.
- National Research Council of Canada, National Building Code of Canada 2020, Appendix C Table C-2 (Halifax: January 2.5 percent design temperature -16 degrees Celsius; the 2.5 percent value is colder for about 19 hours in January on average) and Article 9.33.3.1 (22 degrees Celsius indoor design temperature in living spaces). Checked on 2026-10-30.
- Natural Resources Canada, Air-Source Heat Pump Sizing and Selection Guide (version 1.0, December 2020): sizing to the design heating load, backup heat below the balance point, ton equals 12,000 BTU/h, and the cycling that comes with oversized units. Checked on 2026-10-30.
- Natural Resources Canada, EnerGuide Rating System Open Data (2025 file): design heat loss, year built and floor area of 6,768 single detached houses evaluated in the Halifax area, fitted by age group; Open Government Licence – Canada. Checked on 2026-10-30.
- Natural Resources Canada, Addendum to the Air-Source Heat Pump Sizing and Selection Guide: worked examples: manufacturer capacity data for cold-climate units at low temperatures, the basis for the 90 percent assumption. Checked on 2026-10-30.
Related
FAQ
Common questions
Should I choose a ducted heat pump or a mini-split?
It depends on what you already have. If the house has good ductwork, a ducted heat pump heats every room through it. If it doesn't, or you only want to heat some rooms, mini-split heads on the wall are simpler to fit. Either way, the size comes from the heat your house loses, which is what the calculator estimates.
Do I need one mini-split head or two?
A head heats the room it's in and a little beyond it, so one head rarely heats a whole house with closed doors. The calculator splits the total into the fewest heads it can. How many you actually want depends on your floor plan, so talk it through with your installer.
Can I keep my oil furnace as backup?
Yes. When the calculator shows the heat pump covering less than all of the load at -16 degrees Celsius, the oil furnace, baseboards or wood stove make up the rest on the coldest nights. Plenty of houses keep their old heat for exactly that.
Why isn't a bigger heat pump better?
A unit that's much bigger than the house needs reaches the temperature too quickly, shuts off, and starts again soon after. That on and off cycling wears the equipment and wastes energy. A unit matched to the house runs longer at a steady, low output.
How accurate is this size estimate?
It's a range, not a measurement. Two houses of the same size and age can lose heat quite differently, so the range covers the middle half of similar houses. A heat-loss calculation of your actual house is the only way to get a firm number.
Who works out the right size for my house?
An independent local technician or installer who has seen the house. Ask them for a room-by-room heat-loss calculation before they recommend equipment, and compare their number with the range here.
Free · No obligation
Get a callback
Leave your number and what's going on, and we'll call you back.
Service areas
Areas we serve
Serving Halifax, Nova Scotia and nearby communities. Not sure if you're covered? Call and ask.
- Halifax peninsula
- Clayton Park
- Fairview
- Rockingham
- Armdale
- Spryfield
- Herring Cove
- Bedford
- Hammonds Plains
- Timberlea
- Lakeside and Beechville
- Tantallon
Heat pump acting up? Call now.