Fujitsu heat pump error codes and flashing lights
Your Fujitsu has stopped heating and two little lights on the front are blinking at you. That’s not random. Fujitsu units report problems by flashing their lamps in a set pattern, and once you know how to count them, you’ll know roughly what’s wrong before anyone arrives, and whether there’s something simple you can try first.
Around Halifax
Fujitsu is one of the brands Halifax heat pump installers carry, so a Fujitsu in a Halifax home was most likely put in by a local company. That's good news when something goes wrong: parts and know-how are close by. In Halifax, a blinking Fujitsu very often shows up in the middle of a cold snap, when ice on the outdoor unit is part of the story, so take a look outside before you call. And if you have a multi-zone system, with several indoor heads on one outdoor unit, note which head is blinking and which room it's in. It tells the technician where to start.
Why people choose Fujitsu
- Built for real winters. Fujitsu’s cold-climate models keep heating down to -30 degrees C, and many have a small heater in the base of the outdoor unit so defrost water doesn’t freeze in the tray. That matters in a Halifax freeze-thaw winter.
- A long track record. Fujitsu has been making heat pumps for decades, and its wall units are a familiar sight in Canadian homes.
- Installed and backed locally. Fujitsu is sold through heating dealers, so the company that installed yours can usually service it and get the parts.
- Options for most homes. Single wall units, multi-zone systems that heat several rooms from one outdoor unit, and ducted systems.
- Easy control. Many models take a Wi-Fi adapter, so you can run the heat from your phone.
Before you start
Find the model number on the label on the side of the indoor unit, and snap a photo of it. The code table below comes from Fujitsu’s own service manual for its wall-mounted ASUG09LZAS, ASUG12LZAS and ASUG15LZAS series. Other Fujitsu series, and older units, use different tables, so if your model is different, use this page as a guide and check your own manual. (Halifax Heat Pump Repair isn’t connected with Fujitsu.)
How to read the blinking lights
You’re watching two lamps on the indoor unit: the green Operation lamp and the orange Timer lamp. The third lamp, Economy, stays steady during an error, so you can ignore it.
- Count how many times the green Operation lamp flashes in one group.
- Then count the orange Timer lamp’s flashes.
- Wait for the pattern to repeat, and count again to be sure. A phone video makes this much easier.
- Find the pair in the tables below. One green and one orange is code 11. Five green and eight orange is code 58.
If you have a wired wall controller instead of a handheld remote, it shows the code directly, as E: followed by two characters, like E: 11.
One pattern isn’t an error at all: green and orange blinking together, one second on and one second off. That’s forced cooling, a service mode started by the small button on the indoor unit. Switch the unit off and on with the remote to get back to normal.
Codes you can try something for
Do these once, at your own risk. If the same code comes back, leave it for a technician. Never open the outdoor cabinet or touch the wiring.
| Code | What’s going on | What you can try |
|---|---|---|
| 11 1 green, 1 orange | The indoor and outdoor units have stopped talking to each other. | Common after a power outage or a storm. Switch the heat pump off at the breaker for 5 to 10 minutes, then back on. |
| 12 1 green, 2 orange | The indoor unit lost contact with the wired wall controller. | Do the same breaker reset. If it comes back, the controller or its cable needs a look. |
| 18 1 green, 8 orange | An outside connection failed, often the Wi-Fi adapter. | Restart your internet router, then do the breaker reset. The heat pump may still run fine from the remote. |
| 58 5 green, 8 orange | The intake grille (the front panel that opens) isn’t where the unit expects it. | Make sure the front grille is fully closed and nothing is in the way, then reset at the breaker. |
| 35 3 green, 5 orange | The MANUAL AUTO button on the indoor unit is reading as stuck. | Check nothing is pressing on the button (furniture, a curtain), then reset at the breaker. |
| 97 9 green, 7 orange | The outdoor fan motor isn’t turning properly. | With the power off at the breaker, look for ice, snow or a stick jamming the fan. Don’t reach in. If it’s ice, see heat pump frozen. |
| 94 9 green, 4 orange | Trip detection: the outdoor unit shut itself down. | One breaker reset. If it trips again, call. |
Codes that need a technician
| Code | What’s going on |
|---|---|
| 32 3 green, 2 orange | The indoor unit’s main circuit board has a fault. |
| 41 4 green, 1 orange | The room temperature sensor in the indoor unit has failed. |
| 42 4 green, 2 orange | The sensor on the indoor coil has failed. |
| 51 5 green, 1 orange | The indoor fan motor isn’t working properly. |
| 62 6 green, 2 orange | The outdoor unit’s main circuit board has a fault. |
| 63 6 green, 3 orange | The inverter, which controls the compressor’s speed, has a fault. |
| 64 6 green, 4 orange | The power-correction circuit in the outdoor unit has a fault. |
| 71 7 green, 1 orange | The sensor that watches the compressor’s outlet temperature has failed. |
| 73 7 green, 3 orange | The sensor on the outdoor coil has failed. |
| 74 7 green, 4 orange | The outdoor air temperature sensor has failed. |
| 84 8 green, 4 orange | The current sensor in the outdoor unit has failed. |
| 95 9 green, 5 orange | The compressor isn’t running under proper control. |
| 99 9 green, 9 orange | The 4-way valve, which switches the system between heating, cooling and defrost, isn’t working. |
| A1 10 green, 1 orange | The compressor is running too hot. |
Most of these are a failed sensor, a motor or a circuit board. The good news is that a sensor is often a small part. A board or the compressor is a bigger job. The code tells the technician where to start, but they’ll test the unit before quoting the repair, so ask for the price before any work starts.
Clean filters prevent a lot of trouble
Many Fujitsu units have a filter light that comes on when it’s time to clean the filters. When you see it, slide the filters out from behind the front panel, rinse them in warm water without soap, let them dry completely and put them back. Then press the filter reset button so the light goes off. Doing this about once a month in heating season keeps the airflow up and heads off a lot of the problems above. Heat pump cleaning and maintenance covers the rest.
When to call a technician
If a code comes back after one reset, that’s your answer: it’s not going to clear on its own. Call too if the house is getting cold, if the outdoor unit won’t start or keeps icing up, or if you can’t match the lights to your model. Switch the unit off at the breaker and call right away if you smell burning or a breaker keeps tripping.
When you call, have the model number (that photo of the label), the code or the flash counts, and which head is blinking if you have more than one. Heat pump not heating has more on what to check while you wait.
Sources
Checked on 2026-10-22. Cold-climate features and brand notes checked on 2026-10-26.
- Fujitsu General, Service Manual, Air Conditioner Wall Mounted Type, indoor ASUG09LZAS, ASUG12LZAS, ASUG15LZAS, outdoor AOUG09LZAH1, AOUG12LZAH1, AOUG15LZAH1, document SR_AS025EF_04, 2020.02.26: chapter 3 “Troubleshooting”, section 1-1 “Error code table (Indoor unit and wired remote controller)”, page 03-1; and the forced cooling operation description.
- Fujitsu AIRSTAGE, Mini-split FAQs: filter-clean indicator light.
- Fujitsu cold-climate models (checked 2026-10-26, from search results): dealer and retailer spec pages for the AIRSTAGE XLTH line, e.g. AirGreen and GotDuctless: heating to -30 degrees C (-22 degrees F), base pan heater.
- Halifax installers carrying Fujitsu (checked 2026-10-26, from search results): Hunt’s Heating & Air Conditioning lists Fujitsu among its brands.
- Filter reset button after cleaning: Fujitsu remote and indoor-unit instructions as summarised in search results, checked 2026-10-26.
Related
FAQ
Common questions
How do I read the flashing lights on a Fujitsu mini-split?
Watch two lamps on the indoor unit: the green Operation lamp and the orange Timer lamp. Count how many times each one flashes in a group, then match the pair to the table. One Operation flash and one Timer flash, for example, is code 11.
What does code 11 (1 green, 1 orange flash) mean on a Fujitsu?
The indoor and outdoor units have stopped talking to each other. After a power outage, try one reset: switch the heat pump off at the breaker for 5 to 10 minutes, then back on. If the lights come back, call a technician.
Does every Fujitsu use the same codes?
No. The table here is from Fujitsu's service manual for its ASUG LZAS wall-mounted series. Other series and older models use different tables, so check the model number on your indoor unit and its manual.
Is the Fujitsu error code the same as the number on the wired remote?
For these models, yes. The wired remote shows the same code as E: followed by two characters, such as E: 11 or E: 94.
Can I fix a Fujitsu error code myself?
A few, yes. A code 58 often just means the front grille isn't closed properly, and a communication code after a power cut can clear with one breaker reset. Most codes point to a sensor, a motor or a circuit board, and those need a technician.
Who repairs Fujitsu units in Halifax?
An independent local technician. We pass your request, with the model and code, to them, and they contact you to arrange a visit. You decide whether to go ahead, and you can ask for the price before any work starts.
Free · No obligation
Get a callback
Leave your number and what's going on, and we'll call you back.
Service areas
Areas we serve
Serving Halifax, Nova Scotia and nearby communities. Not sure if you're covered? Call and ask.
- Halifax peninsula
- Clayton Park
- Fairview
- Rockingham
- Armdale
- Spryfield
- Herring Cove
- Bedford
- Hammonds Plains
- Timberlea
- Lakeside and Beechville
- Tantallon
Heat pump acting up? Call now.
Free to call, no obligation. We line up a local heat pump technician for you.